home *** CD-ROM | disk | FTP | other *** search
- GENERAL ELECTRIC MINI II
-
- NOTES: This is a dual NAM portable unit.
- The ESN prefix is 134 decimal, 86 hex (Mitsubishi)
- See file MITSTEST.TXT for test mode information.
- General Electric: 1-800-528-7711
-
- NAM PROGRAMING:
-
- 1. Press PWR key for one second to turn power on.
-
- 2. Wait for wake up cycle to finish & display to clear.
-
- 3. Within ten seconds press and hold the END key while entering
- 6 2 8 2 9 0 5.
-
- 4. Press SEND to store data and increment the step number.
-
- 5. Press END to complete programing and exit at any time.
-
-
- PROGRAMING DATA:
-
- STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION
-
- 01 0 OR 1 DUAL NO DUAL NAM
- 02 10 DIGITS NO1 MIN (AREA CODE & TEL#)
- 03 00000 - 32767 SID1 SYSTEM ID
- 04 0 OR 1 LU1 LOCAL USE MARK
- 05 0 OR 1 EX1 EXTENDED ADDRESS MARK
- 06 0333 OR 0334 IPCH1 INITIAL PAGING CHANNEL
- 07 2 DIGITS ACCOLC1 ACCESS OVERLOAD CLASS
- 08 0 OR 1 PREF1 PREFERRED SYSTEM (0=B,1=A)
- 09 2 DIGITS GIM1 GROUP ID (10 IN USA)
- 10 0 OR 1 RI1 ROAM INHIBIT
- 11 0 OR 1 DTX1 VOX MODE
- 12 0 OR 1 AR1 SYSTEM AUTO REDIAL
-
- If you entered "0" in step 01 go to step 24
-
- 2ND NAM DATA:
-
- 13 10 DIGITS NO2 MIN (AREA CODE & TEL#)
- 14 00000 - 32767 SID2 SYSTEM ID
- 15 0 OR 1 LU2 LOCAL USE MARK
- 16 0 OR 1 EX2 EXTENDED ADDRESS MARK
- 17 0333 OR 0334 IPCH2 INITIAL PAGING CHANNEL
- 18 2 DIGITS ACCOLC2 ACCESS OVERLOAD CLASS
- 19 0 OR 1 PREF2 PREFERRED SYSTEM (0=B, 1=A)
- 20 2 DIGITS GIM2 GROUP ID (10 IN USA)
- 21 0 OR 1 RI2 ROAM INHIBIT
- 22 0 OR 1 DTX2 VOX MODE
- 23 0 OR 1 AR2 SYSTEM AUTO REDIAL
-
- 24 4 DIGITS SEC SECURITY CODE
- 25 0 OR 1 EE END TO END (DTMF) DIALING
- 26 0 OR 1 C TONE CONTINUOUS DTMF
- 27 0 OR 1 AL AUTO LOCK
- 28 0 OR 1 BEEP CALL TIMER AUDIO BEEP
- 29 0 OR 1 BO 3 WATT BOOSTER OPTION
-
- NOTES:
-
- Install lock code with phone out of programing mode, enter FCN 7 SSSS
- LLL CLR, where SSSS is the security code and LLL is the new lock code.
-
- LOCK: F 2. UNLOCK: Enter three digit code, press SEND.
-
- SYSTEM SELECT: F 1 displays current then press one of the following to change:
- 0 = Pref/non pref, 1 = Non pref/pref, 2 = Home only, 3 = Pref only, 4 = Non
- pref only.